¿Cómo podemos ayudarle?

image
Click to enlarge
preview
preview
preview
Back to the product list

Large Cycling Refrigerated Dryers 3,000-40,000 m3/hr (1,800-24,000 cfm)

Ingersoll Rand large capacity refrigerated dryers deliver outstanding value by providing high-quality compressed air, reliably and efficiently. The innovative design of our large cycling dryers maximize energy savings in systems with fluctuating demand, reduce carbon footprint and save floor space. An optional, high-pressure configuration is also available for demanding applications up to 680 psi.

Features

  • Driving efficiency and performance - unprecedented performance from patent pending large capacity heat exchanger (LCX) with 18 - 58% energy efficiency improvement, 25% greater flow capacity and over 1,000% improved thermal conductivity 
  • Maximum reliability - ISO Class 2-4-3 protection along with integrated pre-filters and redundant no-loss drains closely monitored by a smart controller 
  • Lower energy costs – up to 50% savings achieved through significant energy gains delivered by the large capacity heat exchanger 
  • Increased sustainability – via advanced refrigeration circuitry requiring over 45% less charge and up to 47% lower Global Warming Potential (GWP) by using R410A refrigerant to replace R404A 
  • Space-saving design – reduced footprint allows to simplify installation and free up valuable floor space in your manufacturing operation 
  • Optional high-pressure configurations – available for demanding applications up to 680 psi 
  • Multiplex modular design - multiple, independent air treatment modules, each with its own controls and refrigeration system for requirements over 3,000 scfm (5,000 m3/hr) 

Specifications

Ingersoll Rand Cycling Refrigerated Dryers 60 Hz Performance

Model
Flow Rate
m3/hr
Flow Rate
cfm
Connect
Size
in
Air-Cooled
Operating
kW
Water-Cooled
Operating
kW
Dimensions
(Width x Depth x Height)
mm
Dimensions
(Width x Depth x Height)
in
Weight
kg
Weight
lb
DA3000NVC
3,000
1,800
6
5.1
6.6
864 x 2,324 x 2,362
34 x 91.5 x 93
1,363
3,006
DA4000NVC
4,000
2,400
6
13.0
8.2
864 x 2,324 x 2,362
34 x 91.5 x 93
1,432
3,156
DA5000NVC
5,000
3,000
6
14.7
10.1
864 x 2,324 x 2,362
34 x 91.5 x 93
1,478
3,259
DA6000NVC
6,000
3,600
8
10.4
13.4
2,057 x 2,515 x 2,845
81 x 99 x 112
2,922
6,441
DA8000NVC
8,000
4,800
8
26.3
16.7
2,057 x 2,515 x 2,845
81 x 99 x 112
3,058
6,741
DA10000NVC
10,000
6,000
10
29.7
20.5
2,057 x 2,515 x 2,845
81 x 99 x 112
3,252
7,169
DA12000NVC
12,000
7,200
10
39.4
25.0
2,946 x 2,515 x 2,845
116 x 99 x 112
4,611
10,166
DA15000NVC
15,000
9,000
12
44.4
30.6
2,946 x 2,515 x 2,845
116 x 99 x 112
5,032
11,093
DA20000NVC
20,000
12,000
14
59.1
40.7
3,835 x 2,515 x 2,845
151 x 99 x 112
6,821
15,037
DA25000NVC
25,000
15,000
14
73.8
50.8
4,724 x 2,515 x 2,845
186 x 99 x 112
8,379
18,471
DA30000NVC
30,000
18,000
16
88.5
60.9
5,613 x 2,515 x 2,845
221 x 99 x 112
10,249
22,596
DA35000NVC
35,000
21,000
16
103.2
71.0
6,502 x 2,515 x 2,845
256 x 99 x 112
12,005
26,465
DA40000NVC
40,000
24,000
16
118.0
81.1
7,391 x 2,515 x 2,845
291 x 99 x 112
13,749
30,310

 

 

Ingersoll Rand High Pressure Cycling Refrigerated Dryers 60 Hz Performance

Model
Flow Rate
m3/hr
Flow Rate
cfm
Connect
Size
in
Air-Cooled
Operating
kW
Water-Cooled
Operating
kW
Dimensions
(Width x Depth x Height)
mm
Dimensions
(Width x Depth x Height)
in
Weight
kg
Weight
lb
DA5100NVCHP
5,100
3,000
6
10.4
6.6
915 x 2,236 x 2,363
36 x 88 x 93
1,619
3,569
DA7000NVCHP
7,000
4,000
6
13.0
8.3
916 x 2,236 x 2,363
36 x 88 x 93
1,624
3,579
DA10200NVCHP
10,200
6,000
8
20.8
13.2
2,071 x 2,532 x 2,487
82 x 100 x 98
3,357
7,399
DA14000NVCHP
14,000
8,000
8
26.0
16.6
2,071 x 2,532 x 2,487
82 x 100 x 98
3,366
7,419
  • Driving efficiency and performance - unprecedented performance from patent pending large capacity heat exchanger (LCX) with 18 - 58% energy efficiency improvement, 25% greater flow capacity and over 1,000% improved thermal conductivity 
  • Maximum reliability - ISO Class 2-4-3 protection along with integrated pre-filters and redundant no-loss drains closely monitored by a smart controller 
  • Lower energy costs – up to 50% savings achieved through significant energy gains delivered by the large capacity heat exchanger 
  • Increased sustainability – via advanced refrigeration circuitry requiring over 45% less charge and up to 47% lower Global Warming Potential (GWP) by using R410A refrigerant to replace R404A 
  • Space-saving design – reduced footprint allows to simplify installation and free up valuable floor space in your manufacturing operation 
  • Optional high-pressure configurations – available for demanding applications up to 680 psi 
  • Multiplex modular design - multiple, independent air treatment modules, each with its own controls and refrigeration system for requirements over 3,000 scfm (5,000 m3/hr) 

Ingersoll Rand Cycling Refrigerated Dryers 60 Hz Performance

Model
Flow Rate
m3/hr
Flow Rate
cfm
Connect
Size
in
Air-Cooled
Operating
kW
Water-Cooled
Operating
kW
Dimensions
(Width x Depth x Height)
mm
Dimensions
(Width x Depth x Height)
in
Weight
kg
Weight
lb
DA3000NVC
3,000
1,800
6
5.1
6.6
864 x 2,324 x 2,362
34 x 91.5 x 93
1,363
3,006
DA4000NVC
4,000
2,400
6
13.0
8.2
864 x 2,324 x 2,362
34 x 91.5 x 93
1,432
3,156
DA5000NVC
5,000
3,000
6
14.7
10.1
864 x 2,324 x 2,362
34 x 91.5 x 93
1,478
3,259
DA6000NVC
6,000
3,600
8
10.4
13.4
2,057 x 2,515 x 2,845
81 x 99 x 112
2,922
6,441
DA8000NVC
8,000
4,800
8
26.3
16.7
2,057 x 2,515 x 2,845
81 x 99 x 112
3,058
6,741
DA10000NVC
10,000
6,000
10
29.7
20.5
2,057 x 2,515 x 2,845
81 x 99 x 112
3,252
7,169
DA12000NVC
12,000
7,200
10
39.4
25.0
2,946 x 2,515 x 2,845
116 x 99 x 112
4,611
10,166
DA15000NVC
15,000
9,000
12
44.4
30.6
2,946 x 2,515 x 2,845
116 x 99 x 112
5,032
11,093
DA20000NVC
20,000
12,000
14
59.1
40.7
3,835 x 2,515 x 2,845
151 x 99 x 112
6,821
15,037
DA25000NVC
25,000
15,000
14
73.8
50.8
4,724 x 2,515 x 2,845
186 x 99 x 112
8,379
18,471
DA30000NVC
30,000
18,000
16
88.5
60.9
5,613 x 2,515 x 2,845
221 x 99 x 112
10,249
22,596
DA35000NVC
35,000
21,000
16
103.2
71.0
6,502 x 2,515 x 2,845
256 x 99 x 112
12,005
26,465
DA40000NVC
40,000
24,000
16
118.0
81.1
7,391 x 2,515 x 2,845
291 x 99 x 112
13,749
30,310

 

 

Ingersoll Rand High Pressure Cycling Refrigerated Dryers 60 Hz Performance

Model
Flow Rate
m3/hr
Flow Rate
cfm
Connect
Size
in
Air-Cooled
Operating
kW
Water-Cooled
Operating
kW
Dimensions
(Width x Depth x Height)
mm
Dimensions
(Width x Depth x Height)
in
Weight
kg
Weight
lb
DA5100NVCHP
5,100
3,000
6
10.4
6.6
915 x 2,236 x 2,363
36 x 88 x 93
1,619
3,569
DA7000NVCHP
7,000
4,000
6
13.0
8.3
916 x 2,236 x 2,363
36 x 88 x 93
1,624
3,579
DA10200NVCHP
10,200
6,000
8
20.8
13.2
2,071 x 2,532 x 2,487
82 x 100 x 98
3,357
7,399
DA14000NVCHP
14,000
8,000
8
26.0
16.6
2,071 x 2,532 x 2,487
82 x 100 x 98
3,366
7,419