How can we help you?

image
Click to enlarge
Back to the product list

NL Module Coalescing Filters 210 - 17000 Nm3/h

Ingersoll Rand’s NL Module high efficiency and coalescing filters provide compressed air with minimal pressure drop of 35mb for long-term cost savings. Superior air quality is achieved by effectively removing damaging oil and water aerosols before they flow through air system piping, process equipment and pneumatic valves and tools. These maintenance-free filters feature a high-quality design that extends element life up to 10 years and helps eliminate system downtime by reducing the effects of a catastrophic failure of the compressor’s air/oil separator

Features

  • Efficient Equipment Protection: High-efficiency and coalescing filters with particulate filtration to 0.5 ppm, > 3 microns at 100%, between 0.1 to 3 microns at 99.98% . Class 2: effective oil removal – 2 ppm in = 0.01 ppm out – 10 ppm in = 0.05 ppm out 
  • Lower Energy Use: Low pressure drop (around 35mb compare to convetional filters average of 448mb) design saves on energy costs and provides an economical drying solution for your compressed air needs
  • Application Versatility: Effective on all common mineral and synthetic lubricants
  • Class 2: effective oil removal – 2 ppm in = 0.01 ppm out – 10 ppm in = 0.05 ppm out
  • Maximize Uptime: Enhanced process security that reduces the effects of catastrophic air/oil separator failures
  • Extend Equipment Life: High-quality, maintenance-free filters extend element life up to 10 years
  • Real Savings: Near Zero pressure drop and low-maintenance resulting in low energy costs

 

long-life-deep-bed-filtration.png

HOW IT WORKS

Air contaminated with mineral or synthetic lubricant and water aerosols enters the NL Module housing...
1 - Air flows horizontally through a deep filter bed
2 - Sub-micron particles collect on individual bed fibers and coalesce to form droplets
3 - As the droplets move through the filter bed, they become larger and their resulting weight forces them to drop to the bottom of the housing
4 - Low internal velocity prevents oil re-entrainment, while the large surface area keeps the pressure drop very low over the life of the element. The long residence time through the deep filter bed ensures the highest coalescing efficiency. Automatic or manual drains can be used to discharge lubricant and water that accumulate in the bottom of the housing
5 - Compressed air and drain hookups are all that’s required to integrate an NL Module into your compressed air system — no electricity is used. No loss drains are included with each model.

nl-module-working-principle.png

Model Specifications

 

Model
Filter Model number (EMEIA) (CCN)
Flow capacity (Nm3/h)
Flow capacity (m3/min)
Connection Size (A),(B) (in)
Drain Port (C) (in)
Weight (kg)
Dimension (D) (mm)
Dimension (E) (mm)
Dimension (F) (mm)
Dimension (G) (mm)
Dimension (H) (mm)
Dimension Volume (i)
F210INLM
17933082
210
3.5
2" BSPP
1" BSPP
205
353
370
1075
330
180
57
F430INLM
17933083
430
7.2
2" BSPP
1" BSPP
205
353
370
1075
330
180
57
F850INLM
17933084
850
14.2
DN 80 PN16
1" BSPP
234
353
367
1736
330
180
114
F1360INLM
17933085
1360
22.7
DN 80 PN16
1" BSPP
239
353
367
1736
330
180
114
F1870INLM
17933087
1870
31.2
DN 80 PN16
1" BSPP
297
397
394
1837
355
185
160
F2550INLM
17933088
2550
42.5
DN 100 PN16
1" BSPP
349
448
394
1840
381
190
205
F3220INLM
17933089
3220
53.7
DN 100 PN16
1" BSPP
551
601
434
1924
457
210
380
F4070INLM
17933090
4070
67.8
DN 100 PN16
1" BSPP
560
601
434
1924
457
210
380
  • Efficient Equipment Protection: High-efficiency and coalescing filters with particulate filtration to 0.5 ppm, > 3 microns at 100%, between 0.1 to 3 microns at 99.98% . Class 2: effective oil removal – 2 ppm in = 0.01 ppm out – 10 ppm in = 0.05 ppm out 
  • Lower Energy Use: Low pressure drop (around 35mb compare to convetional filters average of 448mb) design saves on energy costs and provides an economical drying solution for your compressed air needs
  • Application Versatility: Effective on all common mineral and synthetic lubricants
  • Class 2: effective oil removal – 2 ppm in = 0.01 ppm out – 10 ppm in = 0.05 ppm out
  • Maximize Uptime: Enhanced process security that reduces the effects of catastrophic air/oil separator failures
  • Extend Equipment Life: High-quality, maintenance-free filters extend element life up to 10 years
  • Real Savings: Near Zero pressure drop and low-maintenance resulting in low energy costs

 

long-life-deep-bed-filtration.png

HOW IT WORKS

Air contaminated with mineral or synthetic lubricant and water aerosols enters the NL Module housing...
1 - Air flows horizontally through a deep filter bed
2 - Sub-micron particles collect on individual bed fibers and coalesce to form droplets
3 - As the droplets move through the filter bed, they become larger and their resulting weight forces them to drop to the bottom of the housing
4 - Low internal velocity prevents oil re-entrainment, while the large surface area keeps the pressure drop very low over the life of the element. The long residence time through the deep filter bed ensures the highest coalescing efficiency. Automatic or manual drains can be used to discharge lubricant and water that accumulate in the bottom of the housing
5 - Compressed air and drain hookups are all that’s required to integrate an NL Module into your compressed air system — no electricity is used. No loss drains are included with each model.

nl-module-working-principle.png

 

Model
Filter Model number (EMEIA) (CCN)
Flow capacity (Nm3/h)
Flow capacity (m3/min)
Connection Size (A),(B) (in)
Drain Port (C) (in)
Weight (kg)
Dimension (D) (mm)
Dimension (E) (mm)
Dimension (F) (mm)
Dimension (G) (mm)
Dimension (H) (mm)
Dimension Volume (i)
F210INLM
17933082
210
3.5
2" BSPP
1" BSPP
205
353
370
1075
330
180
57
F430INLM
17933083
430
7.2
2" BSPP
1" BSPP
205
353
370
1075
330
180
57
F850INLM
17933084
850
14.2
DN 80 PN16
1" BSPP
234
353
367
1736
330
180
114
F1360INLM
17933085
1360
22.7
DN 80 PN16
1" BSPP
239
353
367
1736
330
180
114
F1870INLM
17933087
1870
31.2
DN 80 PN16
1" BSPP
297
397
394
1837
355
185
160
F2550INLM
17933088
2550
42.5
DN 100 PN16
1" BSPP
349
448
394
1840
381
190
205
F3220INLM
17933089
3220
53.7
DN 100 PN16
1" BSPP
551
601
434
1924
457
210
380
F4070INLM
17933090
4070
67.8
DN 100 PN16
1" BSPP
560
601
434
1924
457
210
380